Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. Open Central Data and navigate into Setups and then into Item Options

  2. Click on the Rectangular folder and then on Duct

  3. Check the box to Enable Coil Line Options for Straight Duct

    1. This option will use the Coil Line labor rate for standard length duct. The labor rate is set up in the Data File - Labor Rates section C. Data File - Labor Rates

  4. Check the boxes for each of the components typically formed on the coil line

    1. Fabricate Seam (example; Pittsburgh or Snaplock)

    2. Install Seam Sealant (example; ductsealer injected during seam roll forming)

    3. *Fabricate Joint on the duct (example; TDF or Slip and Drive

    4. Checking these options will NOT include the labor for these component processes with the standard length duct

...