2. Per Joint Setup - Rectangular
Bend Allow – the inches to subtract for the joint connection
...
Override Sealant To – if the max vertical is reached, what sealant to change to
Include Joint Fab Labor - If coil line options have been enabled in the Item Options setup for Duct to not include the joint labor (example; TDF or Slip and Drive formed during coil line process), but this joint requires the labor to be included as the coil does not provide the joint, then check this option.
Available Sealants – the sealant list is pulled from the Joint Sealants page. Check the sealants that are allowed with the joint.
...